microlek-logo
DPS Digital Input Adjustable DC Power Supply 0-30V 0-5A 110V 220V

R3,895.89

DPS series digital input adjustable DC power supply is designed for car, laboratory, school, production lines and electronic repair designed for use. Voltage stability is high, small ripple factor, has improved the short circuit protection and overcurrent protection.

Out of stock

Share Product :

Facebook
Twitter
Pinterest
LinkedIn
SKU MT - 156 Category

Payment Support :

Description

DPS Digital Input Adjustable DC Power Supply 0-30V 0-5A 110V 220V

 

DPS series digital input adjustable DC power supply is designed for laboratory, school, production lines and electronic repair designed for use. Voltage stability is high, small ripple factor, has improved the short circuit protection and overcurrent protection.

Due to the voltage value is a digital keyboard input, shorten the voltage setting time, completely overcome the traditional potentiometer adjustment poor contact caused by voltage instability phenomenon. The internal power supply containing electronic switch, can conveniently open the output load.

DPS – 305 BM : Four digit current display measuring accuracy :
0000-0.450A , ±0.001 A
0.450-5 A , ±0.01 A
DPS – 305 CM : Four digit current display measuring accuracy :
0000-0.450A , ±0.001 A
0.450-5 A , ±0.01 A
DPS – 305 BF  : Five digit current display measuring accuracy :
00000-0.0450A, ±0.0001A
0.0450-0.450A, ± 0.001A
0.450-5 A, ±0.01 A
DPS – 305 CF  : Five digit current display measuring accuracy :
00000-0.0450A, ±0.0001A
0.0450-0.450A, ± 0.001A
0.450-5 A, ±0.01 A
Specification :

1, rated working conditions and dimensions
Power supply voltage 220V + 10%50 / 60Hz
Working conditions : 0-40 temperature relative humidity 80%
Storage temperature : – 10-70 C 70% relative humidity
Dimensions : 265 x 128 x 150mm ( D * W * H )

2, regulated state parameters
The voltage output from 0 to 30V can be continuously adjusted ( to distinguish the value of 0.1V )
The precision of output voltage : + 0.1V
Voltage stability : < 0.01%+3mv
Load stability : < 0.01%+3mv
Recovery time : 100uS
Ripple noise voltage : < 1mVRMS ( 5Hz-1MHz )
Temperature coefficient : < 300PPM / C

3, a constant current state parameters
Constant current value : 305 CM 5A Ma constant current maximum 500 mA
303CM 3A Ma constant current maximum 500 mA
Constant current output current from 0 to the nominal value of continuous adjustable ( to distinguish the value of 0.01A )
Constant current output accuracy : + 0.01A ( MA constant current precision : + 1mA)
The current stability of the < 0.1%+3mA
Load stability < 0.1%+3mA
Ripple noise current < 3mARMS

4, current and voltage display accuracy
Voltage display accuracy : + 0.1V ( constant current state )
Current display accuracy : + 0.01A ( constant pressure )
Ma current display accuracy : + 1mA ( constant pressure )

5, storage capacity
Storage and call ten current, voltage data ( 305 / CM )
Initial has been deposited in the data : 1 keys ( 3V ) 2 ( 5V ) button button 3 ( 9V ) 4 ( 12V ) 5 button button button ( 13.8V ) 6 ( 15V ) 7 ( 18V ) 8 button button button ( 19V ) 9 ( 20V ) 0 ( 24V ) current key value is 5A, the user can arbitrarily settings change the desired voltage and current.

6, a voltage step range
10V / 1V / 0.1V lifting voltage step
Three panel features
In 1, the front panel
Current display window
Voltage display window
Data entry keyboard ( double function keys are : 0 / mA decimal point / latch / ENT / password 4 / stepper
7 / 8 / 9 step step / step / step 2 / 1 step 3 / step )
Constant voltage / ENT indicating lamp
Constant current lamp
Output indicator
Ma status indicator
Power switch
Output ports : ” -” negative polarity ( black )
GND : ground earthing terminal ( green )
Output ports : ” +” the positive ( red )

Using notes:

The initial state power :

Power every time when energized, the first display888-888digital tube display models, and then, on the display a setting voltage and current values, and finally into the working state and output.

The value of the input voltage

A step input
123456keys are 10V / 1V / 0.1V step lifting key, in order to prevent misoperation damage load, lift the 10V must also press 4 and7 or4 and1to lift.
B key input
Column : the need for13.8V output voltage
According to the voltage V respectively by 138press ENT key to finish last.
Column : the need for9V output voltage
According to the voltage V by 9followed by the ENT key is complete.
Column : need to output 4.5V
According to the voltage V by 4.5Finally, press the ENT key is complete.
According to the voltage V respectively by 04.5Finally, press the ENT key and a result is the same as above.
A word with the most complex and the most simple input method the results are the same.
Prompt.

Voltage input data is greater than 300and greater than 30V, instruments do not accept input, return not set before the voltage value. When the keyboard input data do not meet the requirements or input the wrong data, need to be removed to input new data in time, press the V key, so just input voltage data delete disappeared, can enter again. If this time to withdraw from the voltage setting state, only need to press the ENT key is returned ( and to exit the voltage input must press the V button, press ENT key to exit in return ).

Voltage display window a bit word flashing, then power waiting for input the data bits.
V / ENT input confirmation light flashes, indicating apparatus in waits for the user to press the ENT button to confirm.

The value of the input current

Input current value is automatically transferred to the state apparatus constant current constant current value, when the load current is equal to and greater than the constant current value, the power from the voltage state into the automatic constant current state, current limitations in the set value to output, not cut load.

Column : the need for1.38A output current
According to the current I respectively by 1.38finally, press the ENT key is complete.
Column : the need for5A output current
According to the current I directly by5followed by the ENT key is complete.
Column : the need for0.5A output current
According to the current I directly press.5finally press the ENT key is complete.
According to the current I respectively by 0.5Finally, press the ENT key and a result is the same as above.
A word with the most complex and the most simple input method the results are the same.

Prompt.

Voltage input data is greater than500(303BM / CM data to a maximum of 300,3A ) and greater than or equal to 0.00A5A, instrumen

 

A Packing list:
1*DC Power Supply 110V or 220V
1 x Test line
1* Probe
1* Power line(EU/AU/US)

 

B Packing list:
1 x DPS Digital Input Adjustable DC Power Supply
1 x  Test line
2 x  Probe
1 x  Power line(EU/AU/US)
1 x  DC Jack Set
2 x  Phone Repair Power Line
2 x  Test line clamp

Reviews

There are no reviews yet.

Be the first to review “DPS Digital Input Adjustable DC Power Supply 0-30V 0-5A 110V 220V”

Your email address will not be published. Required fields are marked *